Vertical mast lifts

Checking mast lift access through doors, corridors and elevators

A lift must fit both the approach and the elevator cabin. A doorway width on its own does not establish that the machine can enter, turn or leave.

DL double-mast lift

Check the entire vertical transport route

Measure the landing turn, door opening, cabin dimensions and rated load. Include the total weight transported and any removable or folded components permitted by the manufacturer. Ask the building operator to review thresholds, flooring and elevator use for the proposed move.

Stowed dimensions change within a series

AL modelStowed heightNet machine weight
AL6-1001,780 mm950 kg
AL7.5-1001,980 mm1,050 kg

The AL catalogue lists an 820 mm machine width for both. Use actual lifted and transported loads, rather than net machine weight alone, when reviewing an elevator.

Details to record

  • Stowed length, width and height
  • Cabin dimensions and door position
  • Total transported weight at the landing

Can the lift travel in our building elevator?

Measure the clear doorway, car interior and approach space, and record the elevator's rated load. Compare these with the actual transport dimensions and total transported weight. Have the building operator confirm the route and floor conditions.